120W Max Medical Grade 12V 24V AC/DC Power Supply 24V 36V 48volt Medical Charger Transformer

120W Max Medical Grade 12V 24V AC/DC Power Supply 24V 36V 48Volt Medical Charger TransformerProduct Specification:•Power range: 100~200W•Universal AC input 90 to 264 VAC•Frequency: 47 to 63Hz•Efficiency <= 85% depends on models.•Output voltage available from 5 to 56VDC•Safety: UL/cUL 60601-

Featured Products

120W Max Medical Grade 12V 24V AC/DC Power Supply 24V 36V 48Volt Medical Charger Transformer

Product Specification:

•Power range: 100~200W
•Universal AC input 90 to 264 VAC
•Frequency: 47 to 63Hz
•Efficiency <= 85% depends on models.
•Output voltage available from 5 to 56VDC
•Safety: UL/cUL 60601-1, CB IEC60601-1-2, FCC, CE
•All models meet RoHS and WEEE
•Dimensions (L x W x H): 127.0 x 76.3 x 36.2 (mm)
•Weight: 450 grams

 

Features:
• High Efficiency
• CEC Compliance
• RoHS Compliance
• Over Voltage Protective Installation
• Over Current Protective Installation
• Short Circuit Protective Installation
• 100% Burn-In
• 100% Hi-Pot Tested
• MTBF > 50,000 hours

 

INPUT:
• Input Range: 90-264Vac
• Input Current: ≤3.0A
• Inrush Current: ≤120A peak @230VAC,cold start@25°C
• Efficiency: ≤85% depends on models.
• Meet CEC Level VI.
• Turn On Time ≤3S


OUTPUT:

• Over Voltage Protection: Latch off
• Short Circuit Protection: Latch off
• Over Current Protection: Latch off

 

ENVIRONMENTAL:
• Operating Temperature: 0 to 50°C
• Storage Temperature: -20 to 85°C
• Storage Humidity: 5% to 95 %

 

SAFETY:
• UL/cUL 60601-1, CB IEC60601-1-2, FCC, CE

MODEL NO.OUTPUT POWER (W)OUTPUT NO.OUTPUT VOLTAGE (Vdc)OUTPUT LOAD (A)LOAD REGULATIONRIPPLE & NOISE
Single outputEPM1WWWXXYZ80~120WMain Power5, 12, 18, 19, 24, 36, 48V2.5~16A± 5% Max.2% Max.
Dual outputEPM2WWWXXYZ86~110WMain Power5, 12, 19, 24, 36, 48V2.08~16.0A± 5% Max.2% Max.
Stand-by or -12V5Vsb or~12V0.5~2.0A ± 5 or 10% Max.2% Max.
Triple outputEPM3WWWXXYZ90~110WMain Power5, 12, 19, 24, 36, 48V1.96~14.8A± 5% Max.2% Max.
Stand-by Power5Vsb2A± 5% Max.2% Max.
DC-DC or -12V5, 12V or~12V0.5~3A ± 5 or 10% Max.2% Max.
Quad outputEPM4WWWXXYZ110WMain Power12, 19, 24V2.42~7A± 5% Max.2% Max.
DC - DC Power5,12V2~3A± 5% Max.2% Max.
-12V Power-12V0.5A± 10% Max.2% Max.
Stand-by Power5Vsb2A± 5% Max.2% Max.
NOTE:
1 : Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.1uF ceramic capacitor & parallel with 47uF aluminum capacitor at full load and nominal line.
2 : Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.
3 : Max. Power (W) ≥Vo x Io
120W Max Medical Grade 12V 24V AC/DC Power Supply 24V 36V 48volt Medical Charger Transformer

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours